Haemokinesis GEMINI®
Overview
Haemokinesis GEMINI® has been specifically designed around the needs of the Donor centre. The Haemokinesis GEMINI® family of instruments are an extensive range of analyers for Donor related blood grouping and antibody screening.
Consumables
AUTO ABO/D + Reverse (Patient)
A-B-DVI–Ctl.-A1-B
Pack Size: 1x 320 Cards
REF No: TA4002-320*
For ABO Forward and Reverse Grouping in Patients.
AUTO ABO/D + Reverse (Donor)
A-B-DVI+-Ctl.-A1-B
Pack Size: 1x 320 Cards
REF No: TA4003-320*
For ABO Forward and Reverse Grouping in Donors.
AUTO AHG (Anti-Human Globulin)
AHG-AHG-AHG-AHG-AHG-AHG
Pack Size: 1x 320 Cards
REF No: TA4000-320*
For Direct and Indirect Antiglobulin Testing.
AUTO Group Check (Donor)
A-B-DVI+-A-B-DVI+
Pack Size: 1x 320 Cards
REF No: TA4005-320*
For confirmation of ABO and Rh(D) Grouping in Donors (Anti-D detects DVI).
AUTO Group Check (Patient)
A-B-DVI–A-B-DVI
Pack Size: 1x 320 Cards
REF No: TA4004-320*
For confirmation of ABO and Rh(D) Grouping in Patients (Anti-D does not detect DVI).
AUTO ABO/D + DAT
A-B-DVI–DVI–Ctl.-AHG
Pack Size: 1x 320 Cards
REF No: TA4017-320*
For ABO and Rh(D) Grouping (Anti-D does not detect DVI). Inclusion of an AHG well for Direct Antiglobulin Testing.
AUTO ABO/D
A-B-AB-DVI+-DVI–Ctl.
Pack Size: 1x 320 Cards
REF No: TA4015-320*
For ABO and Rh(D) Grouping (the first Anti-D detects DVI and the second Anti-D does not detect DVI).
AUTO AB/D + Reverse
A-B-DVI+-DVI–A1-B
Pack Size: 1x 320 Cards
REF No: TA4019-320*
For ABO and Rh(D) Grouping (the first Anti-D detects DVI and the second Anti-D does not detect DVI).
AUTO Anti-DVI pos
DVI+-DVI+-DVI+-DVI+-DVI+-DVI+
Pack Size: 1x 320 Cards
REF No: TA4021-320*
For DVI Grouping.
AUTO Anti-IgG
IgG-IgG-IgG-IgG-IgG-IgG
Pack Size: 1x 320 Cards
REF No: TA4001-320*
For Indirect Antiglobulin Testing.
AUTO BAS-Test
A-B-IgG-IgG-IgG-IgG
Pack Size: 1x 320 Cards
REF No: TA4018-320*
For ABO Grouping and detection of Irregular Erythrocyte Antibodies.
AUTO DAT
IgG-C3d-Ctl.-IgG-C3d-Ctl.
Pack Size: 1x 320 Cards
REF No: TA4008-320*
For Direct Antiglobulin Testing.
AUTO Neutral
N-N-N-N-N-N
Pack Size: 1x 320 Cards
REF No: TA4010-320*
For Reverse Grouping, Antibody Screening and Identification Procedures and Compatibility Testing.
AUTO Newborn
A-B-AB-DVI+-Ctl.-AHG
Pack Size: 1x 320 Cards
REF No: TA4007-320*
For determination of Neonatal Grouping.
AUTO Rh/Kell I
C-c-E-e-K-Ctl.
Pack Size: 1x 320 Cards
REF No: TA4006-320*
For determination of Rh Phenotype and Kell Typing.
AUTO 2 Cell Screen + Diluent
Pack Size: 1x cell 1 vial, 1x cell 2 vial, 10x 10mL diluent vials
REF No: RC5027*
AUTO 3 Cell Screen + Diluent
Pack Size: 1x cell 1 vial, 1x cell 2 vial, 1x cell 3 vial, 15x 10mL diluent vials
REF No: RC5026*
AUTO Reverse A1 and B Cell + Diluent
Pack Size: 1x A1 cell vial, 1x B cell vial, 10x 10mL diluent vials
REF No: RC5025*
AUTO Reverse A1, A2, B & O Cell + Diluent
Pack Size: 1x A1 cell vial, 1x A2 cell vial, 1x B cell vial, 1x O cell Vial, 20x 10mL diluent vials
REF No: RC5030*
AUTO Screening Cell IV + Diluent
Pack Size: 1x cell IV vial, 5x 10mL diluent vials
REF No: RC5031*
Has received CE mark certification. Product not available for sale in Australia and USA. Not available for distribution in some countries, check with your local distributor for availability.